Provider Name: GULF COAST HEALTH AND REHABILITATION, LLC
Address: 8002 GRELOT ROAD, MOBILE, AL 36695
Phone: (251) 634-8002
County: Mobile (480)
Ownership Type: For profit - Corporation
Certified Beds: 100
Average Residents Per Day: 89.5 ()
Provider Type: Medicare and Medicaid, Resides in Hospital: No
Legal Business Name: GULF COAST HEALTH AND REHABILITATION LLC
First Approved Date: August 2, 2006
Affiliated Entity: NHS MANAGEMENT (372)
Retirement Community: N, Special Focus Status:
Ownership Change in Last 12 Months: N
Resident Family Council: Resident
Sprinkler System Status: Yes
Overall Rating: 2 ()
Health Inspection Rating: 2 ()
QM Rating: 3 ()
Long Stay QM Rating: 4 ()
Short Stay QM Rating: 2 ()
Staffing Rating: 2 ()
Staffing Report Note:
PT Staffing Note:
Nurse Aide Staff Hours Per Day, per resident: 2.74112, LPN Staff Hours Per Day: 1.1050, RN Staff Hours Per Day: 0.2733, Licensed Staff Hours Per Day: 1.3783
Total Nurse Staff Hours Per Day, per resident: 4.11948
Weekend Nurse Staff Hours: 3.51930, Weekend RN Staff Hours: 0.1342
PT Staff Hours Per Day, per resident: 0.0507
Nurse Staff Turnover: 66.4, Nurse Turnover Note:
RN Turnover: 63.6, RN Turnover Note:
Admin Left Number: , Admin Turnover Note: 6
Case Mix Nurse Aide Hours Per Day, per resident: 1.9112, Case Mix LPN Hours Per Day: 0.6510, Case Mix RN Hours Per Day: 0.2880
Adjusted Nurse Aide Hours Per Day, per resident: 2.92185, Adjusted LPN Hours Per Day: 1.2526, Adjusted RN Hours Per Day: 0.3576
Total Adjusted Nurse Hours Per Day, per resident: 4.55565
Adjusted Weekend Nurse Hours Per Day, per resident: 3.89193
Health Survey Dates and Scores: Cycle 1: 2020-01-09 (Score: 32), Cycle 2: 2018-11-08 (Score: 40), Cycle 3: 2018-01-04 (Score: 8)
Total Weighted Health Score: 30.667
Reported Incidents: 0, Substantiated Complaints: 0
Infection Control Citations:
Fines and Penalties: Number of Fines: 0, Total Fines in Dollars: 0.00, Payment Denials Number: 0, Total Penalties Number: 0
Location and GPS: 8002 GRELOT ROAD,MOBILE,AL,36695 (30.6611, -88.214)
Process Date: 2024-03-01
Each record details specific health deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:
Type: Health, Deficiency: Provide appropriate pressure ulcer care and prevent new ulcers from developing.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2020-02-13
Type: Health, Deficiency: Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2020-02-13
Type: Health, Deficiency: Ensure each resident receives and the facility provides food that accommodates resident allergies, intolerances, and preferences, as well as appealing options.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2020-02-13
Type: Health, Deficiency: Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2020-02-13
Type: Health, Deficiency: Provide and implement an infection prevention and control program.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2020-02-13
Type: Health, Deficiency: Keep residents' personal and medical records private and confidential.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Health, Deficiency: Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Health, Deficiency: Dispose of garbage and refuse properly.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Health, Deficiency: Provide and implement an infection prevention and control program.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Health, Deficiency: Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed pharmacist.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-02-08
Type: Health, Deficiency: Provide and implement an infection prevention and control program.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-02-08
Each record details specific fire safety deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:
Type: Fire Safety, Tag: 0920, Version: New
Description: Ensure proper usage of power strips and extension cords.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2020-02-19
Type: Fire Safety, Tag: 0007, Version: New
Description: Address patient/client population and determine types of services needed.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Fire Safety, Tag: 0039, Version: New
Description: Conduct testing and exercise requirements.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Fire Safety, Tag: 0222, Version: New
Description: Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Fire Safety, Tag: 0232, Version: New
Description: Have corridors or aisles that are unobstructed and are at least 8 feet in width.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Fire Safety, Tag: 0345, Version: New
Description: Have approved installation, maintenance and testing program for fire alarm systems.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Fire Safety, Tag: 0781, Version: New
Description: Have restrictions on the use of portable space heaters.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-12-13
Type: Fire Safety, Tag: 0918, Version: New
Description: Have generator or other power source capable of supplying service within 10 seconds.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-02-08
Type: Fire Safety, Tag: 0920, Version: New
Description: Ensure proper usage of power strips and extension cords.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2018-02-08