HEALTHCARE CENTRE OF FRESNO Nursing Home


HEALTHCARE CENTRE OF FRESNO (CCN: 055626) is a For profit - Individual facility located in FRESNO, CA (93721). The facility has an overall rating of 3/5, health inspection rating of 3/5, and a staffing rating of 4/5. It offers 155 certified beds and maintains an average of 121. residents per day. The nursing staff includes Nurse Aides, LPNs, and RNs working 4.00592 total hours per resident per day. It has been certified since February 13, 1967 and the last listed health inspection was on October 5, 2023, The facility is located in Fresno county and provides senior and nursing home care.

HEALTHCARE CENTRE OF FRESNO Summary


Patient Ratings
Please rate how you felt your loved one or yourself have been treated at Healthcare Centre Of Fresno below to help others make a more informed decision. Thank you.
Current Rating: Loading...

Provider Name: HEALTHCARE CENTRE OF FRESNO

Address: 1665 M STREET, FRESNO, CA 93721

Phone: (559) 268-5361

County: Fresno (090)

Ownership Type: For profit - Individual

Certified Beds: 155

Average Residents Per Day: 121. ()

Provider Type: Medicare and Medicaid, Resides in Hospital: No

Legal Business Name: FRESNO SKILLED NURSING & WELLNSS CENTRE, LLC

First Approved Date: February 13, 1967

Affiliated Entity: BRIUS MANAGEMENT (92)

Retirement Community: N, Special Focus Status:

Ownership Change in Last 12 Months: N

Resident Family Council: Resident

Sprinkler System Status: Yes

Overall Rating: 3 ()

Health Inspection Rating: 3 ()

QM Rating: 4 ()

Long Stay QM Rating: 5 ()

Short Stay QM Rating: 3 ()

Staffing Rating: 4 ()

Staffing Report Note:

PT Staffing Note:

Nurse Aide Staff Hours Per Day, per resident: 2.63571, LPN Staff Hours Per Day: 0.7137, RN Staff Hours Per Day: 0.6565, Licensed Staff Hours Per Day: 1.3702

Total Nurse Staff Hours Per Day, per resident: 4.00592

Weekend Nurse Staff Hours: 3.88206, Weekend RN Staff Hours: 0.6014

PT Staff Hours Per Day, per resident: 0.0406

Nurse Staff Turnover: 38.5, Nurse Turnover Note:

RN Turnover: 26.3, RN Turnover Note:

Admin Left Number: 0, Admin Turnover Note:

Case Mix Nurse Aide Hours Per Day, per resident: 1.8861, Case Mix LPN Hours Per Day: 0.6963, Case Mix RN Hours Per Day: 0.3344

Adjusted Nurse Aide Hours Per Day, per resident: 2.84684, Adjusted LPN Hours Per Day: 0.7564, Adjusted RN Hours Per Day: 0.7396

Total Adjusted Nurse Hours Per Day, per resident: 4.32879

Adjusted Weekend Nurse Hours Per Day, per resident: 4.19495

Health Survey Dates and Scores: Cycle 1: 2023-10-05 (Score: 40), Cycle 2: 2019-01-25 (Score: 152), Cycle 3: 2017-10-26 (Score: 76)

Total Weighted Health Score: 83.333

Reported Incidents: 4, Substantiated Complaints: 4

Infection Control Citations:

Fines and Penalties: Number of Fines: 2, Total Fines in Dollars: 1637.65, Payment Denials Number: 0, Total Penalties Number: 2

Location and GPS: 1665 M STREET,FRESNO,CA,93721 (36.7427, -119.794)

Process Date: 2024-03-01


Health Inspection Citations Details

Each record details specific health deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:

Citation on 2023-11-13

Type: Health, Deficiency: Provide appropriate treatment and care according to orders, resident’s preferences and goals.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-12-13

Citation on 2023-10-05

Type: Health, Deficiency: Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-04

Citation on 2023-10-05

Type: Health, Deficiency: Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-04

Citation on 2023-10-05

Type: Health, Deficiency: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-04

Citation on 2023-10-05

Type: Health, Deficiency: Ensure that feeding tubes are not used unless there is a medical reason and the resident agrees; and provide appropriate care for a resident with a feeding tube.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-04

Citation on 2023-10-05

Type: Health, Deficiency: Ensure menus must meet the nutritional needs of residents, be prepared in advance, be followed, be updated, be reviewed by dietician, and meet the needs of the resident.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-04

Citation on 2023-10-05

Type: Health, Deficiency: Ensure food and drink is palatable, attractive, and at a safe and appetizing temperature.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-04

Citation on 2023-02-24

Type: Health, Deficiency: Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-03-24

Citation on 2022-10-05

Type: Health, Deficiency: Ensure services provided by the nursing facility meet professional standards of quality.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-11-03

Citation on 2019-01-25

Type: Health, Deficiency: Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure each resident receives an accurate assessment.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Develop the complete care plan within 7 days of the comprehensive assessment; and prepared, reviewed, and revised by a team of health professionals.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure services provided by the nursing facility meet professional standards of quality.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Assist a resident in gaining access to vision and hearing services.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Employ sufficient staff with the appropriate competencies and skills sets to carry out the functions of the food and nutrition service, including a qualified dietician.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure menus must meet the nutritional needs of residents, be prepared in advance, be followed, be updated, be reviewed by dietician, and meet the needs of the resident.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure food and drink is palatable, attractive, and at a safe and appetizing temperature.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure each resident receives and the facility provides food prepared in a form designed to meet individual needs.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure each resident receives and the facility provides food that accommodates resident allergies, intolerances, and preferences, as well as appealing options.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Ensure therapeutic diets are prescribed by the attending physician and may be delegated to a registered or licensed dietitian, to the extent allowed by State law.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance with accepted professional standards.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Provide and implement an infection prevention and control program.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2019-01-25

Type: Health, Deficiency: Keep all essential equipment working safely.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-04-05

Citation on 2021-05-06

Type: Health, Deficiency: Make sure there is a pest control program to prevent/deal with mice, insects, or other pests.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-08-02

Citation on 2017-10-26

Type: Health, Deficiency: Protect each resident from mistreatment, neglect and misappropriation of personal property.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Provide housekeeping and maintenance services.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Keep the rate of medication errors (wrong drug, wrong dose, wrong time) to less than 5%.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Offer other nutritional food to each resident who will not eat the food served.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Store, cook, and serve food in a safe and clean way.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Maintain drug records and properly mark/label drugs and other similar products according to accepted professional standards.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Have a program that investigates, controls and keeps infection from spreading.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Put firmly secured handrails on each side of hallways.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-10-26

Type: Health, Deficiency: Keep accurate, complete and organized clinical records on each resident that meet professional standards.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26


Fire Safety Citations Details

Each record details specific fire safety deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:

Citation on 2023-10-10

Type: Fire Safety, Tag: 0161, Version: New

Description: Use approved construction type or materials.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0345, Version: New

Description: Have approved installation, maintenance and testing program for fire alarm systems.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0355, Version: New

Description: Properly select, install, inspect, or maintain portable fire extinguishes.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0363, Version: New

Description: Install corridor and hallway doors that block smoke.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0711, Version: New

Description: Provide a written emergency evacuation plan.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0712, Version: New

Description: Have simulated fire drills held at unexpected times.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0918, Version: New

Description: Have generator or other power source capable of supplying service within 10 seconds.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2023-10-10

Type: Fire Safety, Tag: 0920, Version: New

Description: Ensure proper usage of power strips and extension cords.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-10-31

Citation on 2019-01-31

Type: Fire Safety, Tag: 0004, Version: New

Description: Develop and maintain an Emergency Preparedness Program (EP).

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0036, Version: New

Description: Establish emergency prep training and testing.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0161, Version: New

Description: Use approved construction type or materials.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0321, Version: New

Description: Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0324, Version: New

Description: Provide properly protected cooking facilities.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0363, Version: New

Description: Install corridor and hallway doors that block smoke.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0741, Version: New

Description: Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0918, Version: New

Description: Have generator or other power source capable of supplying service within 10 seconds.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2019-01-31

Type: Fire Safety, Tag: 0920, Version: New

Description: Ensure proper usage of power strips and extension cords.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-02-21

Citation on 2017-11-08

Type: Fire Safety, Tag: 0161, Version: New

Description: Use approved construction type or materials.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0222, Version: New

Description: Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0321, Version: New

Description: Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0345, Version: New

Description: Have approved installation, maintenance and testing program for fire alarm systems.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0347, Version: New

Description: Properly provide smoke detection systems in areas open to corridors.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0363, Version: New

Description: Install corridor and hallway doors that block smoke.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0372, Version: New

Description: Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0374, Version: New

Description: Install smoke barrier doors that can resist smoke for at least 20 minutes.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0914, Version: New

Description: Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0918, Version: New

Description: Have generator or other power source capable of supplying service within 10 seconds.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2017-12-26

Citation on 2017-11-08

Type: Fire Safety, Tag: 0923, Version: New

Description: Have proper medical gas storage and administration areas.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.