BROOKSHIRE POST ACUTE Nursing Home


BROOKSHIRE POST ACUTE (CCN: 065242) is a For profit - Corporation facility located in DENVER, CO (80222). The facility has an overall rating of 1/5, health inspection rating of 1/5, and a staffing rating of 3/5. It offers 61 certified beds and maintains an average of 56.1 residents per day. The nursing staff includes Nurse Aides, LPNs, and RNs working 3.51790 total hours per resident per day. It has been certified since October 1, 1988 and the last listed health inspection was on September 29, 2022, The facility is located in Denver county and provides senior and nursing home care.

BROOKSHIRE POST ACUTE Summary


Patient Ratings
Please rate how you felt your loved one or yourself have been treated at Brookshire Post Acute below to help others make a more informed decision. Thank you.
Current Rating: Loading...

Provider Name: BROOKSHIRE POST ACUTE

Address: 4660 E ASBURY CIR, DENVER, CO 80222

Phone: (303) 756-1546

County: Denver (150)

Ownership Type: For profit - Corporation

Certified Beds: 61

Average Residents Per Day: 56.1 ()

Provider Type: Medicare and Medicaid, Resides in Hospital: No

Legal Business Name: BROOKSHIRE HEALTHCARE LLC

First Approved Date: October 1, 1988

Affiliated Entity: PROVIDENCE GROUP (429)

Retirement Community: N, Special Focus Status:

Ownership Change in Last 12 Months: N

Resident Family Council: Both

Sprinkler System Status: Yes

Overall Rating: 1 ()

Health Inspection Rating: 1 ()

QM Rating: 4 ()

Long Stay QM Rating: 4 ()

Short Stay QM Rating: (2)

Staffing Rating: 3 ()

Staffing Report Note:

PT Staffing Note:

Nurse Aide Staff Hours Per Day, per resident: 2.21129, LPN Staff Hours Per Day: 0.7599, RN Staff Hours Per Day: 0.5467, Licensed Staff Hours Per Day: 1.3066

Total Nurse Staff Hours Per Day, per resident: 3.51790

Weekend Nurse Staff Hours: 3.09356, Weekend RN Staff Hours: 0.4499

PT Staff Hours Per Day, per resident: 0.0147

Nurse Staff Turnover: 37.0, Nurse Turnover Note:

RN Turnover: 63.6, RN Turnover Note:

Admin Left Number: , Admin Turnover Note: 6

Case Mix Nurse Aide Hours Per Day, per resident: 2.0873, Case Mix LPN Hours Per Day: 0.6253, Case Mix RN Hours Per Day: 0.2747

Adjusted Nurse Aide Hours Per Day, per resident: 2.15822, Adjusted LPN Hours Per Day: 0.8967, Adjusted RN Hours Per Day: 0.7499

Total Adjusted Nurse Hours Per Day, per resident: 3.71172

Adjusted Weekend Nurse Hours Per Day, per resident: 3.26401

Health Survey Dates and Scores: Cycle 1: 2022-09-29 (Score: 211), Cycle 2: 2021-06-24 (Score: 16), Cycle 3: 2019-06-27 (Score: 28)

Total Weighted Health Score: 115.50

Reported Incidents: 0, Substantiated Complaints: 4

Infection Control Citations:

Fines and Penalties: Number of Fines: 3, Total Fines in Dollars: 53495.25, Payment Denials Number: 1, Total Penalties Number: 4

Location and GPS: 4660 E ASBURY CIR,DENVER,CO,80222 (39.6796, -104.933)

Process Date: 2024-03-01


Health Inspection Citations Details

Each record details specific health deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:

Citation on 2023-10-12

Type: Health, Deficiency: Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect by anybody.

Severity: G - Level 3: Actual harm that is not immediate jeopardy. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-08

Citation on 2023-10-12

Type: Health, Deficiency: Timely report suspected abuse, neglect, or theft and report the results of the investigation to proper authorities.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-22

Citation on 2023-10-12

Type: Health, Deficiency: Respond appropriately to all alleged violations.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-13

Citation on 2023-10-12

Type: Health, Deficiency: Ensure services provided by the nursing facility meet professional standards of quality.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-13

Citation on 2023-10-12

Type: Health, Deficiency: Provide appropriate pressure ulcer care and prevent new ulcers from developing.

Severity: G - Level 3: Actual harm that is not immediate jeopardy. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-13

Citation on 2023-10-12

Type: Health, Deficiency: Provide appropriate care for a resident to maintain and/or improve range of motion (ROM), limited ROM and/or mobility, unless a decline is for a medical reason.

Severity: G - Level 3: Actual harm that is not immediate jeopardy. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-11-22

Citation on 2022-09-29

Type: Health, Deficiency: Honor the resident's right to request, refuse, and/or discontinue treatment, to participate in or refuse to participate in experimental research, and to formulate an advance directive.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect by anybody.

Severity: J - Level 4: Immediate jeopardy to resident health or safety. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Protect each resident from separation (from other residents, his/her room, or confinement to his/her room).

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Provide safe and appropriate respiratory care for a resident when needed.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Provide the appropriate treatment and services to a resident who displays or is diagnosed with dementia.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Ensure medication error rates are not 5 percent or greater.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Ensure that residents are free from significant medication errors.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Arrange for the provision of hospice services or assist the resident in transferring to a facility that will arrange for the provision of hospice services.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Set up an ongoing quality assessment and assurance group to review quality deficiencies and develop corrective plans of action.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Provide and implement an infection prevention and control program.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2022-09-29

Type: Health, Deficiency: Ensure staff are vaccinated for COVID-19

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-10-04

Citation on 2021-06-24

Type: Health, Deficiency: Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-07-16

Citation on 2021-06-24

Type: Health, Deficiency: Provide appropriate treatment and care according to orders, resident’s preferences and goals.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-07-16

Citation on 2021-06-24

Type: Health, Deficiency: Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-07-16

Citation on 2019-06-27

Type: Health, Deficiency: Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-07-19

Citation on 2019-06-27

Type: Health, Deficiency: Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-07-19

Citation on 2019-06-27

Type: Health, Deficiency: Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-07-19


Fire Safety Citations Details

Each record details specific fire safety deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:

Citation on 2022-10-25

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-11-08

Citation on 2022-10-25

Type: Fire Safety, Tag: 0521, Version: New

Description: Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-11-28

Citation on 2022-10-25

Type: Fire Safety, Tag: 0914, Version: New

Description: Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-11-28

Citation on 2022-10-25

Type: Fire Safety, Tag: 0918, Version: New

Description: Have generator or other power source capable of supplying service within 10 seconds.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-11-22

Citation on 2021-07-20

Type: Fire Safety, Tag: 0345, Version: New

Description: Have approved installation, maintenance and testing program for fire alarm systems.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-09-11

Citation on 2021-07-20

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-08-30

Citation on 2021-07-20

Type: Fire Safety, Tag: 0521, Version: New

Description: Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Waiver has been granted on 2021-10-20

Citation on 2021-07-20

Type: Fire Safety, Tag: 0918, Version: New

Description: Have generator or other power source capable of supplying service within 10 seconds.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2021-08-18

Citation on 2019-07-26

Type: Fire Safety, Tag: 0222, Version: New

Description: Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-07-26

Citation on 2019-07-26

Type: Fire Safety, Tag: 0223, Version: New

Description: Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-07-26

Citation on 2019-07-26

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2019-07-26

Citation on 2019-07-26

Type: Fire Safety, Tag: 0521, Version: New

Description: Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Waiver has been granted on 2019-07-26