CONCORD CARE CENTER Nursing Home


CONCORD CARE CENTER (CCN: 165364) is a For profit - Corporation facility located in GARNER, IA (50438). The facility has an overall rating of 5/5, health inspection rating of 5/5, and a staffing rating of 3/5. It offers 66 certified beds and maintains an average of 39.8 residents per day. The nursing staff includes Nurse Aides, LPNs, and RNs working 3.56645 total hours per resident per day. It has been certified since September 18, 1997 and the last listed health inspection was on August 24, 2023, The facility is located in Hancock county and provides senior and nursing home care.

CONCORD CARE CENTER Summary


Patient Ratings
Please rate how you felt your loved one or yourself have been treated at Concord Care Center below to help others make a more informed decision. Thank you.
Current Rating: Loading...

Provider Name: CONCORD CARE CENTER

Address: 490 WEST LYON STREET, GARNER, IA 50438

Phone: (641) 923-2677

County: Hancock (400)

Ownership Type: For profit - Corporation

Certified Beds: 66

Average Residents Per Day: 39.8 ()

Provider Type: Medicare and Medicaid, Resides in Hospital: No

Legal Business Name: ABCM CORPORATION

First Approved Date: September 18, 1997

Affiliated Entity: ABCM CORPORATION (2)

Retirement Community: N, Special Focus Status:

Ownership Change in Last 12 Months: N

Resident Family Council: None

Sprinkler System Status: Yes

Overall Rating: 5 ()

Health Inspection Rating: 5 ()

QM Rating: 2 ()

Long Stay QM Rating: 2 ()

Short Stay QM Rating: 2 ()

Staffing Rating: 3 ()

Staffing Report Note:

PT Staffing Note:

Nurse Aide Staff Hours Per Day, per resident: 2.35911, LPN Staff Hours Per Day: 0.8077, RN Staff Hours Per Day: 0.3996, Licensed Staff Hours Per Day: 1.2073

Total Nurse Staff Hours Per Day, per resident: 3.56645

Weekend Nurse Staff Hours: 3.08605, Weekend RN Staff Hours: 0.2686

PT Staff Hours Per Day, per resident: 0.0056

Nurse Staff Turnover: 50.9, Nurse Turnover Note:

RN Turnover: 50.0, RN Turnover Note:

Admin Left Number: , Admin Turnover Note: 6

Case Mix Nurse Aide Hours Per Day, per resident: 1.8856, Case Mix LPN Hours Per Day: 0.6297, Case Mix RN Hours Per Day: 0.2824

Adjusted Nurse Aide Hours Per Day, per resident: 2.54875, Adjusted LPN Hours Per Day: 0.9465, Adjusted RN Hours Per Day: 0.5332

Total Adjusted Nurse Hours Per Day, per resident: 4.01797

Adjusted Weekend Nurse Hours Per Day, per resident: 3.47675

Health Survey Dates and Scores: Cycle 1: 2023-08-24 (Score: 4), Cycle 2: 2022-05-05 (Score: 0), Cycle 3: 2020-10-22 (Score: 0)

Total Weighted Health Score: 2.000

Reported Incidents: 2, Substantiated Complaints: 0

Infection Control Citations: 0

Fines and Penalties: Number of Fines: 0, Total Fines in Dollars: 0.00, Payment Denials Number: 0, Total Penalties Number: 0

Location and GPS: 490 WEST LYON STREET,GARNER,IA,50438 (43.0905, -93.608)

Process Date: 2024-03-01


Health Inspection Citations Details

Each record details specific health deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:

Citation on 2023-12-08

Type: Health, Deficiency: Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2024-01-08


Fire Safety Citations Details

Each record details specific fire safety deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:

Citation on 2023-08-30

Type: Fire Safety, Tag: 0013, Version: New

Description: Develop Emergency Preparedness policies and procedures.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-09-14

Citation on 2023-08-30

Type: Fire Safety, Tag: 0039, Version: New

Description: Conduct testing and exercise requirements.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-09-30

Citation on 2023-08-30

Type: Fire Safety, Tag: 0211, Version: New

Description: Keep aisles, corridors, and exits free of obstruction in case of emergency.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-08-31

Citation on 2023-08-30

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-08-31

Citation on 2023-08-30

Type: Fire Safety, Tag: 0363, Version: New

Description: Install corridor and hallway doors that block smoke.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-09-05

Citation on 2023-08-30

Type: Fire Safety, Tag: 0374, Version: New

Description: Install smoke barrier doors that can resist smoke for at least 20 minutes.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2023-09-30

Citation on 2022-05-10

Type: Fire Safety, Tag: 0004, Version: New

Description: Develop and maintain an Emergency Preparedness Program (EP).

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-18

Citation on 2022-05-10

Type: Fire Safety, Tag: 0271, Version: New

Description: Have exits that are accessible at all times.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-11

Citation on 2022-05-10

Type: Fire Safety, Tag: 0321, Version: New

Description: Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-18

Citation on 2022-05-10

Type: Fire Safety, Tag: 0354, Version: New

Description: Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-11

Citation on 2022-05-10

Type: Fire Safety, Tag: 0901, Version: New

Description: Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-18

Citation on 2022-05-10

Type: Fire Safety, Tag: 0918, Version: New

Description: Have generator or other power source capable of supplying service within 10 seconds.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-11

Citation on 2022-05-10

Type: Fire Safety, Tag: 0919, Version: New

Description: Meet requirements for the use of electrical equipment.

Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2022-05-19

Citation on 2020-10-27

Type: Fire Safety, Tag: 0321, Version: New

Description: Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2020-11-02

Citation on 2020-10-27

Type: Fire Safety, Tag: 0353, Version: New

Description: Inspect, test, and maintain automatic sprinkler systems.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2020-11-02

Citation on 2020-10-27

Type: Fire Safety, Tag: 0511, Version: New

Description: Have properly installed electrical wiring and gas equipment.

Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.

Corrected: Deficient, Provider has date of correction on 2020-11-02