Provider Name: EDGEWOOD CONVALESCENT HOME
Address: 513 BELL STREET, EDGEWOOD, IA 52042
Phone: (563) 928-6461
County: Clayton (210)
Ownership Type: For profit - Corporation
Certified Beds: 58
Average Residents Per Day: 44.3 ()
Provider Type: Medicare and Medicaid, Resides in Hospital: No
Legal Business Name: EDGEWOOD CONVALESCENT HOME INC
First Approved Date: January 1, 1998
Affiliated Entity: ()
Retirement Community: N, Special Focus Status:
Ownership Change in Last 12 Months: N
Resident Family Council: Resident
Sprinkler System Status: Yes
Overall Rating: 5 ()
Health Inspection Rating: 5 ()
QM Rating: 4 ()
Long Stay QM Rating: 4 ()
Short Stay QM Rating: 5 ()
Staffing Rating: 4 ()
Staffing Report Note:
PT Staffing Note:
Nurse Aide Staff Hours Per Day, per resident: 2.12748, LPN Staff Hours Per Day: 0.3277, RN Staff Hours Per Day: 0.7594, Licensed Staff Hours Per Day: 1.0872
Total Nurse Staff Hours Per Day, per resident: 3.21468
Weekend Nurse Staff Hours: 2.63043, Weekend RN Staff Hours: 0.4379
PT Staff Hours Per Day, per resident: 0.0201
Nurse Staff Turnover: 54.0, Nurse Turnover Note:
RN Turnover: 50.0, RN Turnover Note:
Admin Left Number: 0, Admin Turnover Note:
Case Mix Nurse Aide Hours Per Day, per resident: 1.8151, Case Mix LPN Hours Per Day: 0.6003, Case Mix RN Hours Per Day: 0.2759
Adjusted Nurse Aide Hours Per Day, per resident: 2.38780, Adjusted LPN Hours Per Day: 0.4028, Adjusted RN Hours Per Day: 1.0369
Total Adjusted Nurse Hours Per Day, per resident: 3.76475
Adjusted Weekend Nurse Hours Per Day, per resident: 3.08053
Health Survey Dates and Scores: Cycle 1: 2023-10-05 (Score: 4), Cycle 2: 2022-06-09 (Score: 4), Cycle 3: 2021-08-19 (Score: 0)
Total Weighted Health Score: 3.333
Reported Incidents: 0, Substantiated Complaints: 0
Infection Control Citations:
Fines and Penalties: Number of Fines: 5, Total Fines in Dollars: 8152.30, Payment Denials Number: 0, Total Penalties Number: 5
Location and GPS: 513 BELL STREET,EDGEWOOD,IA,52042 (42.6414, -91.402)
Process Date: 2024-03-01
Each record details specific health deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:
Type: Health, Deficiency: Ensure services provided by the nursing facility meet professional standards of quality.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2023-10-06
Type: Health, Deficiency: Notify the resident or the resident’s representative in writing how long the nursing home will hold the resident’s bed in cases of transfer to a hospital or therapeutic leave.
Severity: B - Level 1: No actual harm with potential for minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2022-06-10
Type: Health, Deficiency: Have the Quality Assessment and Assurance group have the required members and meet at least quarterly
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2022-06-10
Each record details specific fire safety deficiencies found during inspections, categorized by type, severity, and whether they were corrected. Below are the severity levels and their implications:
Type: Fire Safety, Tag: 0039, Version: New
Description: Conduct testing and exercise requirements.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2023-10-26
Type: Fire Safety, Tag: 0223, Version: New
Description: Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2023-10-12
Type: Fire Safety, Tag: 0321, Version: New
Description: Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
Severity: D - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2023-10-10
Type: Fire Safety, Tag: 0345, Version: New
Description: Have approved installation, maintenance and testing program for fire alarm systems.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2023-11-09
Type: Fire Safety, Tag: 0291, Version: New
Description: Install emergency lighting that can last at least 1 1/2 hours.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2022-06-24
Type: Fire Safety, Tag: 0321, Version: New
Description: Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2022-06-21
Type: Fire Safety, Tag: 0761, Version: New
Description: To conduct inspection, testing and maintenance of fire doors by qualified individuals.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2022-06-30
Type: Fire Safety, Tag: 0918, Version: New
Description: Have generator or other power source capable of supplying service within 10 seconds.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2022-06-27
Type: Fire Safety, Tag: 0353, Version: New
Description: Inspect, test, and maintain automatic sprinkler systems.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2021-08-31
Type: Fire Safety, Tag: 0918, Version: New
Description: Have generator or other power source capable of supplying service within 10 seconds.
Severity: F - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2021-09-01
Type: Fire Safety, Tag: 0926, Version: New
Description: Ensure that personnel concerned with handling of medical gases and cylinders are trained on the risk.
Severity: E - Level 2: No actual harm with potential for more than minimal harm. Plan of Correction required.
Corrected: Deficient, Provider has date of correction on 2021-09-01